At any place, for any task and ready for use at any time, or, in other words: highly mobile, extremely flexible and everything on board.
This was the desire of many of our customers, which we adopted entirely as an ambitious challenge.
As in the workshop, everything was to be connected and immediately ready for use. Also, tools and working materials should be complete and ready to hand.
This also meant that shielding gas and suction would have to be fixedly attached to the mobile device.
The term “mobility” was also to be redefined and largely exceed the transport rollers which had been used so far.
In addition to the newly defined rollers with jacking option, easy transport by forklift truck, pallet truck or even by crane were on the requirement list.
Nothing was abandoned or dropped for financial reasons: the new ToolRoom was to meet all requirements and leave nothing to be desired.
The first outlines already showed that with the tool room we were to create something new which was to meet the requirements of the market exactly.
The pilot production was already sold before the first laser was mounted.
Available as 150W, 300W and 450W FSS laser.
The LWI V ToolRoom is optionally available with an automatic, joystick-controlled crawler chassis:
Technical Data | LWI V FSS 150 W |
---|---|
laser safety class | 4 |
beam source | FSS FullSolidState Fibrelaser, Diodes |
wavelength | 1070 nm |
max. pulse energy | 15 Joule |
max. peak power | 1,5 kW |
max. average power | 150 W |
energy adjustment mode | current |
voltage | 10 - 100 % |
pulse width | 0,1 - 50 ms /cw |
pulse frequency | 1-100 hz |
pulse fill | - |
PWM mode | 1 - 100 % |
focal length | 190 mm |
beam diameter | 100 µm - 2mm, motorized beam-expander |
microscope | Leica binocular, oculars magnification 20x |
illumination of workplace | dual LED cold-light, switchable |
parameter settings memory | 50 settings, individual named |
energy measurement system | integrated |
controller | multi-controller-system, self-diagnostic-system, plaintext for maintenance and status messages |
interface | RS232, CAN-Bus |
shielding gas supply | flexible nozzle, adjustable gas delay |
cooling system | integrated, closed, temperature controlled fan |
cooling option | - |
electrical supply | 1-phasig, 90-250V, 50/60 hz |
power consumption | 800 W |
Dimensions | 1200 x 1627 x 960 |
Technical Data | LWI V FSS 300 W |
---|---|
laser safety class | 4 |
beam source | FSS FullSolidState Fibrelaser, Diodes |
wavelength | 1070 nm |
max. pulse energy | 30 Joule |
max. peak power | 3 kW |
max. average power | 300 W |
energy adjustment mode | current |
voltage | 10 - 100 % |
pulse width | 0,1 - 50 ms /cw |
pulse frequency | 1-100 hz |
pulse fill | - |
PWM mode | 1 - 100 % |
focal length | 190 mm |
beam diameter | 100 µm - 2mm, motorized beam-expander |
microscope | Leica binocular, oculars magnification 20x |
illumination of workplace | dual LED cold-light, switchable |
parameter settings memory | 50 settings, individual named |
energy measurement system | integrated |
controller | multi-controller-system, self-diagnostic-system, plaintext for maintenance and status messages |
interface | RS232, CAN-Bus |
shielding gas supply | flexible nozzle, adjustable gas delay |
cooling system | integrated, closed, temperature controlled fan |
cooling option | - |
electrical supply | 1 Phase , 90-250V, 50/60 hz |
power consumption | 1,2 kW |
Dimensions | 1200 x 1627 x 960 |
Technical Data | LWI V FSS 450 W |
---|---|
laser safety class | 4 |
beam source | FSS FullSolidState Fibrelaser, Diodes |
wavelength | 1070 nm |
max. pulse energy | 45 Joule |
max. peak power | 4,5 kW |
max. average power | 450 W |
energy adjustment mode | current |
voltage | 10 - 100 % |
pulse width | 0,1 - 50 ms /cw |
pulse frequency | 1-100 hz |
pulse fill | - |
PWM mode | - |
focal length | 190 mm |
beam diameter | 100 µm - 2mm, motorized beam-expander |
microscope | Leica binocular, oculars magnification 20x |
illumination of workplace | dual LED cold-light, switchable |
parameter settings memory | 50 settings, individual named |
energy measurement system | integrated |
controller | multi-controller-system, self-diagnostic-system, plaintext for maintenance and status messages |
interface | RS232, CAN-Bus |
shielding gas supply | flexible nozzle, adjustable gas delay |
cooling system | integrated, closed, temperature controlled fan |
cooling option | - |
electrical supply | 1 Phase , 90-250V, 50/60 hz |
power consumption | 2,5 kW |
Dimensions | 1200 x 1627 x 960 |
Technical Data | LWI V FSS 600W |
---|---|
laser safety class | 4 |
beam source | FSS FullSolidState Fibrelaser, Diodes |
wavelength | 1070 nm |
max. pulse energy | 60 Joule |
max. peak power | 6 kW |
max. average power | 600 W |
energy adjustment mode | current |
voltage | 10 - 100 % |
pulse width | 0,1 - 50 ms /cw |
pulse frequency | 1-100 hz |
pulse fill | |
PWM mode | |
focal length | 190 mm (120 mm, 300 mm) |
beam diameter | 100 µm - 2mm, motorized beam-expander |
microscope | Leica binocular, oculars magnification 20x |
illumination of workplace | dual LED cold-light, switchable |
parameter settings memory | 50 settings, individual named |
energy measurement system | integrated |
controller | multi-controller-system, self-diagnostic-system, plaintext for maintenance and status messages |
interface | RS232, CAN-Bus |
shielding gas supply | flexible nozzle, adjustable gas delay |
cooling system | integrated, closed, temperature controlled fan |
cooling option | |
electrical supply | 1 Phase , 90-250V, 50/60 hz |
power consumption | 2,5 kW |
Dimensions | 1200 x 1627 x 960 |
shielding gas and suction are fixedly attached to the mobile device.
tools and working materials are complete and ready to hand